SmartPro SMART1000RM2U, LCD, 1000 VA/800 W, Sine Wave, 2U Rackmount/Tower UPS
Tripp Lite's SMART 1000RM2U intelligent, line-interactive sine wave rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges.
- 1kVA / 1000VA / 800W line interactive 2U rack/tower UPS
- Corrects brownouts and overvoltages from 83V to 147V
- 95% line-mode efficiency
- USB, RS232, EPO and slot for SNMPWEBCARD option
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 1000 |
Output kVA Capacity (kVA) | 1.0 |
Output Watt Capacity (Watts) | 800 |
Power Factor | 0.8 |
Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
Nominal Voltage Details | 120v nominal output in battery mode |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -21%, +8% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (6) 5-15R |
Load Management Receptacles | Two switchable two-outlet 5-15R load banks |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
Rated input current (Maximum Load) | 9.2A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 15A |
UPS Input Cord Length (ft.) | 10 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
Full Load Runtime (min.) | 5.3 min. (800w) |
Half Load Runtime (min.) | 15 min. (400w) |
DC System Voltage (VDC) | 24 |
Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge | See Tripp Lite UPS Replacement battery selector |
Battery Access | Front panel battery access door |
Battery Replacement Description | Hot-swappable, user replaceable batteries |
Expandable Runtime | No |
VOLTAGE REGULATION | |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 |
Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage Correction | Input voltages between 83 and 107 are boosted by 14% |
USER INTERFACE, ALERTS & CONTROLS | |
Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Audible Alarm | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
SURGE / NOISE SUPPRESSION | |
UPS AC Suppression Joule Rating | 570 |
UPS AC Suppression Response Time | Instantaneous |
EMI / RFI AC Noise Suppression | Yes |
PHYSICAL | |
Included Mounting Accessory Description | 4 post rackmount installation accessories included |
Installation Form Factors Supported with Optional Accessories | 2 post rackmount(2POSTRMKITWM); Wallmount(2POSTRMKITWM); Tower(2-9USTAND) |
Primary Form Factor | Rackmount |
UPS Power Module Dimensions (hwd, in.) | 3.45 x 17.35 x 12.5 |
Rack Height (U Spaces) | 2 |
Minimum Required Rack Depth (inches) | 15.5 |
UPS Power Module Weight (lbs.) | 35.4 |
UPS Shipping Dimensions (hwd / in.) | 9 x 24 x 20.2 |
Shipping Weight (lbs.) | 46.4 |
Cooling Method | Fan |
UPS Housing Material | Steel |
Minimum Required Rack Depth (mm) | 394 |
Primary UPS Height (mm) | 88 |
Primary UPS Width (mm) | 441 |
Primary UPS Depth (mm) | 318 |
Shipping Height (mm) | 229 |
Shipping Width (mm) | 610 |
Shipping Depth (mm) | 513 |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) | 134 |
Battery Mode BTU / Hr. (Full Load) | 600 |
AC Mode Efficiency Rating (100% Load) | 95% |
COMMUNICATIONS | |
Communications Interface | USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network Management Cards | SNMPWEBCARD; TLNETCARD; WEBCARDLX |
Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable | USB and DB9 cabling included |
WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Network UPS Tools Compatibility | NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite |
LINE / BATTERY TRANSFER | |
Transfer Time | 4 milliseconds (AC to battery), 2 milliseconds (Battery to AC) |
Low Voltage Transfer to Battery Power (Setpoint) | 83 |
High Voltage Transfer to Battery Power (Setpoint) | 147 |
SPECIAL FEATURES | |
Grounding Lug | Back panel grounding lug |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
High Availability UPS Features | Hot swappable batteries |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year warranty, 3 year with registration. Note: Registration is requiredfor 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |